Control cabinet
The control cabinet includes the following components
- Main control unit (Raspberry Pi)
- Relay actuation unit
- Power supply 12V
- Fuses
- Circuit breaker
- Main switch
- Relays for manual control of pumps and skimmer
- Sockets for power output to pumps and skimmer
Requirements
- The control cabinet shall have the possibility to cut off the connection to the power supply (all wires).
- The control cabinet shall limit the current drawn from the power supply.
- The control cabinet shall limit the current drawn by each actuator (all pumps, skimmer, feeder, heater, ventilation fans).
- The control cabinet shall provide switches accessible without opening the cabinet allowing to switch off the following devices:
- Protein skimmer
- Main pump #1
- Main pump #2
- Auxiliary pump #1
- Auxiliary pump #2
- Heater
- Feeder
- The control cabinet shall provide power sockets for the following devices:
- Protein skimmer
- Main pump #1
- Main pump #2
- Auxiliary pump #1
- Auxiliary pump #2
- Heater
- The control cabinet shall provide signal indicator lamps for the following devices:
- Protein skimmer
- Main pump #1
- Main pump #2
- Auxiliary pump #1
- Auxiliary pump #2
- Heater
- The control cabinet shall provide a rail mount terminal block for all 12V devices:
- all Balling mineral dosing pumps
- fresh-water refill pump
- ventilation fan #1
- ventilation fan #2
- The control cabinet shall provide a rail mount terminal block for all 230V devices that do not use a power socket:
- feeder
- The control cabinet shall allow to route all cables (power supply, actuators, sensors) to outside of the cabinet - preferably at the bottom of the cabinet.